Temperature Instrumentation for Research and Industry

Products


Connector & Stripanels - Connector Head Types

Micro Connector Heads:

For Mounting directly on thermocouple sheath stem by compression fitting. Large head terminal screws facilitate tight connections. Bodies are molded of high performance thermoset compounds (will not melt) for high strength and dependability. The color coded micro heads will withstand ambient temperatures to 400°F (205°C) continuous 500°F (260°C) intermittent. High-Temperature micro heads (ALL Hi-Temp micro heads are color coded red) will withstand ambient temperatures to 800°F (425°C) continuous and 1000°F (540°C) intermittent.

Angle bracket made of nickel plated steel provides means for firm surface mounting; can be spot welded for permanent mounting or screw mounted through holes provided.


MICRO HEAD
Single Circuit
Code No.
Dual Circuit
Code No.
2010-(*)-( )1 2210-(*)-( )1
HI-TEMP MICRO HEAD
Single Circuit
Code No.
Dual Circuit
Code No.
2110-(*)-( )1 2310-(*)-( )1
MICRO HEAD WITH BRACKET
Single Circuit
Code No.
Dual Circuit
Code No.
2011-(*)-( )1 2211-(*)-( )1
HI-TEMP MICRO HEAD WITH BRACKET
Single Circuit
Code No.
Dual Circuit
Code No.
2111-(*)-( )1 2311-(*)-( )1
*Specify Type J,K,T,E,R,S,CU,N
1-Specify Sheath Size 1/16, 1/8, 3/16, 1/4

Miniature Weatherproof Heads:

Miniature Weatherproof Connecting Head is designed for termination of single or dual thermocouples, RTD's and strain gauges. Pipe threads are provided for probe mounting and extension wire fittings. Probe mount thread accomodates 1/4 NPT or 3/8 NPT. Cover includes gasket to seal against moisture, and chain to prevent loss. Molded of reinforced thermoset compounds, standard head can be used in ambient temperatures to 350°F (175°C); Hi-Temp head to 800°F (425°C).

Four separate connections are provided with individual circuit and polarity markings. Jab-in® terminals eliminate looped wire ends and make wiring easy and positive. Molded channels guide wire between large-head screws and copper terminal inserts. Accepts wire from 32 ga. to 14 ga.


Marlin Part No. Probe Mount Thread Description
2002 1/4 NPT Standard
350°F
2003 3/8 NPT Standard
350°F
2102 1/4 NPT Hi-Temp
800°F
2103 3/8 NPT Hi-Temp
800°F

Mounting Accessories:

Brass Compression Fitting includes body, nut and ferrule for mounting probe tubing.

Marlin Part No. Thread Size Tube Size O.D.
A 14B 125 1/4 NPT 1/8"
A 14B 187 1/4 NPT 3/16"
A 14B 250 1/4 NPT 1/4"
A 38B 375 3/8 NPT 3/8"

Stainless Steel Fixed Fitting for brazing to probe.

Marlin Part No. Thread Size Tube Size O.D.
F 14S 125 1/4 NPT 1/8"
F 14S 187 1/4 NPT 3/16"
F 14S 250 1/4 NPT 1/4"
F 38S 375 3/8 NPT 3/8"

Wire Grip Fitting - Marlin Catalog No. 2080 (1/4 NPT) provides strain relief and moisture-proof protection for extension wires from 1/8" OD to 3/8" OD. Contains 1/4 NPT brass body, nut, two sizes of back up washers and four assorted sizes of elastomer grommets.

Mounting Accessories:

Brass Compression Fitting includes body, nut and ferrule for mounting probe tubing.

Marlin Part No. Thread Size Tube Size O.D.
A 14B 125 1/4 NPT 1/8"
A 14B 187 1/4 NPT 3/16"
A 14B 250 1/4 NPT 1/4"
A 38B 375 3/8 NPT 3/8"

Stainless Steel Fixed Fitting for brazing to probe.

Marlin Part No. Thread Size Tube Size O.D.
F 14S 125 1/4 NPT 1/8"
F 14S 187 1/4 NPT 3/16"
F 14S 250 1/4 NPT 1/4"
F 38S 375 3/8 NPT 3/8"

Wire Grip Fitting - Marlin Catalog No. 2080 (1/4 NPT) provides strain relief and moisture-proof protection for extension wires from 1/8" OD to 3/8" OD. Contains 1/4 NPT brass body, nut, two sizes of back up washers and four assorted sizes of elastomer grommets.

Weatherproof Terminal Head:

Weatherproof Heads are rugged cast aluminum or cast iron screw cover units that are available in various NPT probe connection sizes and the choice of terminal block to fit your application.


Marlin Code No. Probe NPT Description
WA 2 1/2 Cast Aluminum
Weatherproof Head
WA 3 3/4 NPT
WA 4 1 NPT
WC 2 1/2 NPT Cast Iron
Weatherproof Head
WC 3 3/4 NPT
WC 4 1 NPT
To order terminal head/block assembly use block code as prefix e.g. 2WA2.

Terminal Blocks for Weatherproof Heads:

T'Block Code Terminal Blocks
A 2-Wire
Accepts up to 8 ga. Wire
D 4-Wire
Accepts up to 8 ga. Wire
2 Rigid 4-Wire
3* Rigid 4-Wire
W/Sheath Adapter
Max Sheath OD = 0.250"
4* Spring Loaded 4-Wire
(1/4" Sheath Size)
5* Spring Loaded 6-Wire
(1/4" Sheath Size)
6 Spring Loaded 4-Wire
(3/16" Sheath Size Only)
*Specify sheath size with these blocks. e.g. TB-3-250 or TB-3-375
ORDER CODE: TB-CODE NO.

Explosion Proof Terminal Head:

Explosion Proof Heads are cast aluminum screw cover units that comply with NEC (National Electrical Code)

  • Class I, Group C,D
  • Class II, Groups E,F,G
  • Class III
  • UL Standard 866

They are designed for use in hazardous environments where extreme caution must be observed.

Marlin Code No. Probe NPT Description
EX A 1/2 NPT

Explosion Proof Head Cast Aluminum

To order terminal head/block assembly use block code as prefix e.g. 2EXA.

Terminal Blocks for Explosion Proof Heads:

T'Block Code Terminal Blocks
3 Rigid 4-Wire
8* Spring Loaded 4-Wire
(1/4" Sheath Size Only)
*Specify sheath size with these blocks. e.g. TB-8-250
ORDER CODE: TB-CODE NO.

General Purpose Head:

General Purpose Heads are rugged cast aluminum units with stamped steel covers that are available in various NPT probe connection sizes and terminal block to fit your application.


Marlin Code No. Probe NPT Description
GP 2 1/2 NPT Cast Aluminum
General Purpose Head
GP 3 3/4 NPT
GP 4 1 NPT
To order terminal head/block assembly use block code as prefix e.g. 1GP2.

Terminal Blocks for General Purpose Heads:

T'Block Code Terminal Blocks
1 Rigid 4-Wire
8* 2-Wire
Accepts up to 8 ga. Wire
ORDER CODE: TB-CODE NO.

Marlin Open Head:

The Open Head ia a brass body head with post terminals, T/C male plugs, or T/C female jacks. Dual thermocouple open heads are also available in post, plug, or jack styles. Designed primarily for use with platinum/rhodium type thermocouples. No terminal block is used with this head.

For more information regarding Connector Heads
Consult your Marlin Catalog.